Guard and watch tower

ExperimentalUpdated: 2026-10-19

What the system calculates

You choose the structure (steel or timber), platform height, cabin, walkway around it, stairs or ladder, railing, floodlights and cameras. The system calculates:

- pad footings, legs and cross bracing every 3 m of height;

- platform beams, joists and decking;

- stair flights with landings or a ladder;

- railing with balusters at the chosen spacing;

- the cabin frame, cladding, insulation, windows, door and mono-pitch roof;

- floodlights, cameras and a video recorder.

Steel tower: 4 m platform, 2 × 2 m cabin, 0.6 m walkway, stairs, a floodlight and two cameras
Steel tower: 4 m platform, 2 × 2 m cabin, 0.6 m walkway, stairs, a floodlight and two cameras · View generated by Statyk from sample parameters.

Hunting tower

A simpler option is a timber platform with a small roof on four posts and a ladder. A ladder above 3 m is awkward and risky, so the system suggests stairs or a caged ladder.

Timber 3 m tower: 1.6 × 1.6 m platform, small roof and a ladder
Timber 3 m tower: 1.6 × 1.6 m platform, small roof and a ladder · View generated by Statyk from sample parameters.

Tall tower

For a taller tower the stairs are split into flights of up to 3 m with landings. From 6 m the legs, bracing, footings and wind load must be designed by a structural engineer — the system shows quantities, not member sizes.

7 m tower: insulated 2.4 × 2.4 m cabin, six windows, stairs in two flights
7 m tower: insulated 2.4 × 2.4 m cabin, six windows, stairs in two flights · View generated by Statyk from sample parameters.

Permits and neighbours

- A technical observation tower is an engineering structure (STR 1.01.03 Annex 3 row 4.5). Up to 15 m its group depends on K = S × H³: group I up to 10,000, group II up to 40,000.

- Above 15 m it is a non-special structure and always needs a permit. A roofed one of 20 m or more is a special structure.

- If the cabin is most of the structure, the tower may count as a building: group I up to 5 m and 50 m², group II up to 8.5 m and 80 m². The category is unclear, so the system shows both.

- Closer than 1 m to the boundary — the neighbour's consent. A roofed tower 1–3 m from the boundary needs consent if it is taller than the distance.

Railings

Building rules require a guard from 1.5 m, railings at least 0.9 m high and gaps between balusters of at most 120 mm. From 2027 external stairs and landings need at least 1.2 m. For a tower these apply by analogy, so the default railing is 1.2 m.

Start with this example

Example project: drawings and material quantities