Skip to content

DEMO · Demo version for testing — results are not final.

Farm building 15 × 20 m or Farm building 15 × 20 m, open?

Both examples are generated with the same parameters; only the walls differs. Quantities include waste, no prices – the generator shows the price from the catalogue. A preliminary result, not a design.

Key facts

ClosedOpen wallsDifference
Footprint15 × 20 m15 × 20 m
Built-up area300 m²300 m²=
Wall height5 m5 m=
Ridge height7.01 m7.01 m=
Labour hours624 h504 h−120 h (-19 %)
Material lines2822−6
Materials (incl. waste, incl. VAT)€35,154.61€26,965.65−€8,188.96 (-23 %)

Preliminary prices from catalogue lt-2026-10 (2026-10-25). This is an example, not an offer: supplier prices vary and labour depends on your rate – you enter it and your own materials in the generator. Catalogue prices are still being verified.

Structural engineer approval required

Material quantities

Lines that differ come first; “—” means the material is not used in that variant.

MaterialUnitClosedOpen wallsDifference
Wind barrier membraneWallsm²400.57—−400.57
Rectangular tube 60×40×2 (gate frame)Wallsm220.5—−220.5
Trapezoidal polycarbonate, clear (light band)External claddingm²47.08—−47.08
Wall steel sheet T20External claddingm²381.53—−381.53
Sectional overhead gateOpeningsm²16—−16
Rectangular tube 60×40×2 (gate frame)Openingsm12.81—−12.81
Self-drilling screws 35 mmFastenerspcs6,1052,740−3,365
Column anchor bolt setFoundationset1414=
Concrete C20/25Foundationm³3.763.76=
Formwork (boards / panels, rental)Foundationm²19.7119.71=
Crushed stone / gravel 0–32Floorm³64.4764.47=
Concrete C20/25Floorm³46.1546.15=
GeotextileFloorm²322.34322.34=
Rebar mesh 150x150Floorm²322.34322.34=
Column base plate with stiffeners (I-section)Wallspcs1414=
Wind bracing rod Ø16 with turnbucklesWallsm59.459.4=
Lattice column (80x80x3 chords, 40x40x2 diagonals)Wallsm71.471.4=
Roof underlayRoofm²365.96365.96=
Roof steel sheet T35Roofm²402.42402.42=
Wind bracing rod Ø16 with turnbucklesRoofm79.7879.78=
Z-section purlin 150Roofm235.1235.1=
Truss joint set (post connections, apex, bolts)Roofset55=
Lattice truss rafter, galvanised (chords and diagonals)Roofm82.3782.37=
Downpipe 100 mmRainwater drainagem26.2526.25=
Gutter 150 mmRainwater drainagem43.2643.26=
Gutter bracketRainwater drainagepcs6969=
Anchor bolt M12Fastenerspcs7272=
Post connectorFastenerspcs1515=

Start with “Closed”Start with “Open walls”

All comparisons · Find a specialist to prepare or check the design

Rule set lt-v1, catalogue lt-2026-10.